%0 Journal Article %K Reptil %K Atmungstrakt %K Bildqualität %K Röntgen %B Berliner und Münchener Tierärztliche Wochenschrift %C Hannover %D 2010 %G German %I Schlütersche Verlagsgesellschaft mbH & Co. KG %P 177-185 %R 10.2376/0005-9366-123-177 %T Vergleichende röntgenologische Darstellung des Respirationstraktes von Schlangen mittels konventioneller hochauflösender Film-Folien-Kombination und einem digitalen Detektorsystem %V 123 %1 {"oldId":70578,"title":"Vergleichende r\u00f6ntgenologische Darstellung des Respirationstraktes von Schlangen mittels konventioneller hochaufl\u00f6sender Film-Folien-Kombination und einem digitalen Detektorsystem","topline":"","teaserText":"","content":"

Zusammenfassung<\/span>
Zur r\u00f6ntgenologischen Darstellung des Respirationstraktes bei Schlangen wurde eine konventionelle hochaufl\u00f6sende Film-Folien-Kombination (Film Kodak MIN-R S, Verst\u00e4rkerfolie Kodak MIN-R 2000) mit einem digitalen Detektorsystem (Varian PaxScan 4030E) verglichen, wobei die Digitalaufnahme bei gleicher und bei halbierter Dosis erstellt wurde. Die Untersuchung wurde bei 20 Tigerpythons (Python molurus)<\/span> in jeweils dorsoventraler und laterolateraler Projektion durchgef\u00fchrt. Es wurden zu den anatomischen Regionen Lunge, Trachea und Wirbels\u00e4ule je vier Kriterien (drei Merkmale, eine Gesamtbewertung) definiert und in einem Punktesystem in einer halbverblindeten Studie von f\u00fcnf Tier\u00e4rzten bewertet. Der Vergleich der Bewertungen zwischen den Techniken erfolgte mittels Visual-Grading-Analyse. Zur Lunge wurden zwei von drei Merkmalen sowie die Gesamtbeurteilung in den digitalen Belichtungen signifikant besser bewertet. Die Trachea wurde in der Gesamtwertung sowie einem Merkmal in der konventionellen Belichtung signifikant besser beurteilt. F\u00fcr die Wirbels\u00e4ule ergab sich in der Gesamtwertung eine signifikant bessere Beurteilung der digitalen Aufnahme bei voller Dosis, sowohl die konventionelle als auch die digitale Belichtung bei reduzierter Dosis wurden in je einem Merkmal signifikant schlechter bewertet. Die Studie zeigt die Vorteile der digitalen Radiografie f\u00fcr die Beurteilung des bei Schlangen eher kontrastarmen Respirationstraktes. Grenzen ergeben sich bei der Darstellung sehr kleiner Strukturen. Eine Dosisreduktion im Vergleich zur konventionellen hochaufl\u00f6senden Film-Folien-Kombination ist f\u00fcr die Darstellung des Respirationstraktes grunds\u00e4tzlich m\u00f6glich.

Schl\u00fcsselw\u00f6rter:<\/span>
Reptil, Atmungstrakt, Bildqualit\u00e4t, R\u00f6ntgen


Summary<\/span>
A conventional high-resolution screen-film-system (film Kodak MIN-R S, screen Kodak MIN-R 2000) was compared to a digital detector system (Varian PaxScan 4030E) for the evaluation of the respiratory tract in snakes. Digital radiographs were taken with the same dose as well as with half the dose used for the conventional radiographs. A total of 20 Burmese pythons (Python molurus)<\/span> were examined in dorsoventral and lateral projection. Four criteria (three features, one overall assessment) were defined for each of the anatomical structures lung, trachea and spinal column and assessed by five veterinarians in a semi-blinded study using a score system. Comparison of the ratings between the techniques used was done using a visual grading analysis. For the lung, two of the three features as well as the overall assessment were rated significantly superior using the digital system. The trachea was rated significantly superior using the conventional system for the overall assessment as well as for one feature. For the spinal column, the overall assessment was significantly superior using the digital system with the full dose. Conventional radiography as well as digital radiography using half the dose was rated significantly inferior for one feature each. The study demonstrates the advantage of the digital technique for the assessment of the relatively low-contrast respiratory tract. A limiting factor is the demonstration of particularly small structures. Generally, a dose reduction (compared to a conventional high-resolution film-screen-system) is possible for the evaluation of the respiratory system.

Keywords:<\/span>
reptile, respiratory system, imaging quality, x-ray <\/p>","categories":["Open Access","Tier\u00e4rztliche Wochenschrift","Abostufe BMTW","Fachartikel","Abostufe frei"],"fromDate":"Apr 20, 2010 12:00:00 AM","toDate":"Dec 31, 2050 12:00:00 AM","oldUrls":["http:\/\/vetline.de\/reptil-atmungstrakt-bildqualitaet-roentgen\/150\/3130\/70578","http:\/\/vetline.de\/reptil-atmungstrakt-bildqualitaet-roentgen\/150\/3216\/70578"],"doiLanguage":"deutsch","doiProductFormat":"Online","doiPublisher":"Schl\u00fctersche Verlagsgesellschaft mbH & Co. KG","doiSerialWorkTitle":"Berl. M\u00fcnch. Tier\u00e4rztl. Wschr.","doiDocumentUri":"http:\/\/www.vetline.de\/reptil-atmungstrakt-bildqualitaet-roentgen\/150\/3130\/70578","doiSource":"Berl. M\u00fcnch. Tier\u00e4rztl. Wschr. 123: 5-6, 177-185 (2010)","doiissn":"0005-9366","doiNr":"10.2376\/0005-9366-123-177","doiFirstPage":"177","doiLastPage":"185","doiTransmitted":true,"doiAuthor":"Pees M, Bochmann M, Krautwald-Junghanns ME, Schmidt V, Ludewig E","pdf":{"path":"http:\/\/data\/bmtw_2010_05_0177.pdf","title":"bmtw - Vergleichende r\u00f6ntgenologische Darstellung des Respirationstraktes von Schlangen mittels konventioneller hochaufl\u00f6sender ","description":""},"authors":[{"firstName":"M","middleName":"","lastName":"Pees"},{"firstName":"M","middleName":"","lastName":"Bochmann"},{"firstName":"M","middleName":"E","lastName":"Krautwald-Junghanns"},{"firstName":"V","middleName":"","lastName":"Schmidt"},{"firstName":"E","middleName":"","lastName":"Ludewig"}],"contentOptimised":"

Zusammenfassung<\/strong>
Zur r\u00f6ntgenologischen Darstellung des Respirationstraktes bei Schlangen wurde eine konventionelle hochaufl\u00f6sende Film-Folien-Kombination (Film Kodak MIN-R S, Verst\u00e4rkerfolie Kodak MIN-R 2000) mit einem digitalen Detektorsystem (Varian PaxScan 4030E) verglichen, wobei die Digitalaufnahme bei gleicher und bei halbierter Dosis erstellt wurde. Die Untersuchung wurde bei 20 Tigerpythons (Python molurus)<\/em> in jeweils dorsoventraler und laterolateraler Projektion durchgef\u00fchrt. Es wurden zu den anatomischen Regionen Lunge, Trachea und Wirbels\u00e4ule je vier Kriterien (drei Merkmale, eine Gesamtbewertung) definiert und in einem Punktesystem in einer halbverblindeten Studie von f\u00fcnf Tier\u00e4rzten bewertet. Der Vergleich der Bewertungen zwischen den Techniken erfolgte mittels Visual-Grading-Analyse. Zur Lunge wurden zwei von drei Merkmalen sowie die Gesamtbeurteilung in den digitalen Belichtungen signifikant besser bewertet. Die Trachea wurde in der Gesamtwertung sowie einem Merkmal in der konventionellen Belichtung signifikant besser beurteilt. F\u00fcr die Wirbels\u00e4ule ergab sich in der Gesamtwertung eine signifikant bessere Beurteilung der digitalen Aufnahme bei voller Dosis, sowohl die konventionelle als auch die digitale Belichtung bei reduzierter Dosis wurden in je einem Merkmal signifikant schlechter bewertet. Die Studie zeigt die Vorteile der digitalen Radiografie f\u00fcr die Beurteilung des bei Schlangen eher kontrastarmen Respirationstraktes. Grenzen ergeben sich bei der Darstellung sehr kleiner Strukturen. Eine Dosisreduktion im Vergleich zur konventionellen hochaufl\u00f6senden Film-Folien-Kombination ist f\u00fcr die Darstellung des Respirationstraktes grunds\u00e4tzlich m\u00f6glich.

Schl\u00fcsselw\u00f6rter:<\/strong>
Reptil, Atmungstrakt, Bildqualit\u00e4t, R\u00f6ntgen


Summary<\/strong>
A conventional high-resolution screen-film-system (film Kodak MIN-R S, screen Kodak MIN-R 2000) was compared to a digital detector system (Varian PaxScan 4030E) for the evaluation of the respiratory tract in snakes. Digital radiographs were taken with the same dose as well as with half the dose used for the conventional radiographs. A total of 20 Burmese pythons (Python molurus)<\/em> were examined in dorsoventral and lateral projection. Four criteria (three features, one overall assessment) were defined for each of the anatomical structures lung, trachea and spinal column and assessed by five veterinarians in a semi-blinded study using a score system. Comparison of the ratings between the techniques used was done using a visual grading analysis. For the lung, two of the three features as well as the overall assessment were rated significantly superior using the digital system. The trachea was rated significantly superior using the conventional system for the overall assessment as well as for one feature. For the spinal column, the overall assessment was significantly superior using the digital system with the full dose. Conventional radiography as well as digital radiography using half the dose was rated significantly inferior for one feature each. The study demonstrates the advantage of the digital technique for the assessment of the relatively low-contrast respiratory tract. A limiting factor is the demonstration of particularly small structures. Generally, a dose reduction (compared to a conventional high-resolution film-screen-system) is possible for the evaluation of the respiratory system.

Keywords:<\/strong>
reptile, respiratory system, imaging quality, x-ray <\/p>","primaryLanguage":"deutsch","zusammenfassung":"Zur r\u00f6ntgenologischen Darstellung des Respirationstraktes bei Schlangen wurde eine konventionelle hochaufl\u00f6sende Film-Folien-Kombination (Film Kodak MIN-R S, Verst\u00e4rkerfolie Kodak MIN-R 2000) mit einem digitalen Detektorsystem (Varian PaxScan 4030E) verglichen, wobei die Digitalaufnahme bei gleicher und bei halbierter Dosis erstellt wurde. Die Untersuchung wurde bei 20 Tigerpythons (Python molurus)<\/em> in jeweils dorsoventraler und laterolateraler Projektion durchgef\u00fchrt. Es wurden zu den anatomischen Regionen Lunge, Trachea und Wirbels\u00e4ule je vier Kriterien (drei Merkmale, eine Gesamtbewertung) definiert und in einem Punktesystem in einer halbverblindeten Studie von f\u00fcnf Tier\u00e4rzten bewertet. Der Vergleich der Bewertungen zwischen den Techniken erfolgte mittels Visual-Grading-Analyse. Zur Lunge wurden zwei von drei Merkmalen sowie die Gesamtbeurteilung in den digitalen Belichtungen signifikant besser bewertet. Die Trachea wurde in der Gesamtwertung sowie einem Merkmal in der konventionellen Belichtung signifikant besser beurteilt. F\u00fcr die Wirbels\u00e4ule ergab sich in der Gesamtwertung eine signifikant bessere Beurteilung der digitalen Aufnahme bei voller Dosis, sowohl die konventionelle als auch die digitale Belichtung bei reduzierter Dosis wurden in je einem Merkmal signifikant schlechter bewertet. Die Studie zeigt die Vorteile der digitalen Radiografie f\u00fcr die Beurteilung des bei Schlangen eher kontrastarmen Respirationstraktes. Grenzen ergeben sich bei der Darstellung sehr kleiner Strukturen. Eine Dosisreduktion im Vergleich zur konventionellen hochaufl\u00f6senden Film-Folien-Kombination ist f\u00fcr die Darstellung des Respirationstraktes grunds\u00e4tzlich m\u00f6glich.","schluesselwoerter":["Reptil","Atmungstrakt","Bildqualit\u00e4t","R\u00f6ntgen"],"summary":"A conventional high-resolution screen-film-system (film Kodak MIN-R S, screen Kodak MIN-R 2000) was compared to a digital detector system (Varian PaxScan 4030E) for the evaluation of the respiratory tract in snakes. Digital radiographs were taken with the same dose as well as with half the dose used for the conventional radiographs. A total of 20 Burmese pythons (Python molurus)<\/em> were examined in dorsoventral and lateral projection. Four criteria (three features, one overall assessment) were defined for each of the anatomical structures lung, trachea and spinal column and assessed by five veterinarians in a semi-blinded study using a score system. Comparison of the ratings between the techniques used was done using a visual grading analysis. For the lung, two of the three features as well as the overall assessment were rated significantly superior using the digital system. The trachea was rated significantly superior using the conventional system for the overall assessment as well as for one feature. For the spinal column, the overall assessment was significantly superior using the digital system with the full dose. Conventional radiography as well as digital radiography using half the dose was rated significantly inferior for one feature each. The study demonstrates the advantage of the digital technique for the assessment of the relatively low-contrast respiratory tract. A limiting factor is the demonstration of particularly small structures. Generally, a dose reduction (compared to a conventional high-resolution film-screen-system) is possible for the evaluation of the respiratory system.","keywords":["reptile","respiratory system","imaging quality","x-ray"],"translatedTitle":"","abstractE":"Zur r\u00f6ntgenologischen Darstellung des Respirationstraktes bei Schlangen wurde eine konventionelle hochaufl\u00f6sende Film-Folien-Kombination (Film Kodak MIN-R S, Verst\u00e4rkerfolie Kodak MIN-R 2000) mit einem digitalen Detektorsystem (Varian PaxScan 4030E) verglichen, wobei die Digitalaufnahme bei gleicher und bei halbierter Dosis erstellt wurde. Die Untersuchung wurde bei 20 Tigerpythons (Python molurus) in jeweils dorsoventraler und laterolateraler Projektion durchgef\u00fchrt. Es wurden zu den anatomischen Regionen Lunge, Trachea und Wirbels\u00e4ule je vier Kriterien (drei Merkmale, eine Gesamtbewertung) definiert und in einem Punktesystem in einer halbverblindeten Studie von f\u00fcnf Tier\u00e4rzten bewertet. Der Vergleich der Bewertungen zwischen den Techniken erfolgte mittels Visual-Grading-Analyse. Zur Lunge wurden zwei von drei Merkmalen sowie die Gesamtbeurteilung in den digitalen Belichtungen signifikant besser bewertet. Die Trachea wurde in der Gesamtwertung sowie einem Merkmal in der konventionellen Belichtung signifikant besser beurteilt. F\u00fcr die Wirbels\u00e4ule ergab sich in der Gesamtwertung eine signifikant bessere Beurteilung der digitalen Aufnahme bei voller Dosis, sowohl die konventionelle als auch die digitale Belichtung bei reduzierter Dosis wurden in je einem Merkmal signifikant schlechter bewertet. Die Studie zeigt die Vorteile der digitalen Radiografie f\u00fcr die Beurteilung des bei Schlangen eher kontrastarmen Respirationstraktes. Grenzen ergeben sich bei der Darstellung sehr kleiner Strukturen. Eine Dosisreduktion im Vergleich zur konventionellen hochaufl\u00f6senden Film-Folien-Kombination ist f\u00fcr die Darstellung des Respirationstraktes grunds\u00e4tzlich m\u00f6glich.","date":{"year":2010,"date":"04\/2010","accepted":"2010-04-20"},"volume":"123","openAccess":true,"journal":"Berliner und M\u00fcnchener Tier\u00e4rztliche Wochenschrift","titleImageId":944,"pages":"177-185","redirects":["reptil-atmungstrakt-bildqualitaet-roentgen\/150\/3130\/70578","reptil-atmungstrakt-bildqualitaet-roentgen\/150\/3216\/70578"],"tierartCategories":[],"artikelartCategories":["Open Access","Tier\u00e4rztliche Wochenschrift","Abostufe BMTW","Fachartikel","Abostufe frei"]} %8 04/2010